Wireless track lighting for easy installationFocus Industries DB-12 12.5V Direct Burial Magnetic Transformer, 1 Core

Select Wattage 60W 100W
Qty:

Focus Industries DB-12 12.5V Direct Burial Magnetic Transformer, 1 Core

New: Optional Die Cast Brass Lid For Small Db-12-60Led, Db-12-75E

  • Heavy duty, high temperature, fiberglass reinforced composite construction
  • 1/2" NPS & 3/4" NPS bottom hubs for line voltage input, feed through & low voltage output
  • 1/2" NPS hubs on cover for fixture and or photocell mounting (consult factory for details)
  • 120 volt primary, 12.5v secondary, 50/60hz standard
  • Multi Volt 12.5v / 13.5v / 14.5v options available (see Transformer Options below)
  • Isolation type magnetic transformer - no contact between 120v and 12v windings
  • (compact electronic transformers available, see ordering information below)
  • Magnetic circuit breaker for secondary overload/short circuit protection
  • Long life, high temperature (130°C) transformer core
  • Single phase, open core and coil
  • Completely potted for longer life, more efficiency and reduced noise
  • 2 feet of 12/2 direct burial cable for low voltage connections (1 per circuit and/or voltage tap)
  • 1/2" NPS mounting hubs available on cover (specify at time of order if tapping required)
  • NEMA12 rated enclosure for below grade direct burial applications
  • UL 1838 and UL 1598 certified
  • 3 year warranty on enclosure and mechanical/electrical components

Transformer Options

  • MV 12.5v / 13.5v / 14.5v Multi Voltage output on any single circuit transformer
  • MV1 (1) 12.5v / 13.5v / 14.5v Multi Voltage output on 2, 3 or 4 circuit transformer
  • MV2 (2) 12.5v / 13.5v / 14.5v Multi Voltage outputs on 2, 3 or 4 circuit transformer
  • MV3 (3) 12.5v / 13.5v / 14.5v Multi Voltage outputs on 3 or 4 circuit transformer
  • MV4 (4) 12.5v / 13.5v / 14.5v Multi Voltage outputs on 4 circuit transformer
  • PC Photocell mounted on top
  • RPC Remote photocell with 19' cord
  • R 24V AC Relay control. (For use with existing irrigation controllers)
  • 220V 220v Input / 12.5v output in 300w increments (no multi voltage)
  • 240V 240v Input / 12.5v output in 300w increments (no multi voltage)
  • 277V 270v Input / 12.5v output in 300w increments (no multi voltage)

Important Notice: Low voltage electronic transformers must be tested under load with a analog meter to achieve accurate results. Testing the transformer with a digital meter will produce an invalid reading of "no output". This characteristic is unique to electronic transformers that produce a square sine wave. We recommend use of an analog meter for testing with the transformer loaded to at least 20% of its rated output. Most electronic transformers returned as defective are actually good due to testing methods in the field that did not follow the above requirements.